• slideshow1
  • slideshow2
  • slideshow3
  • slideshow4

Gastroenterology


1. Flexible Endoscopes

We have wide range of Video & Fiber Optic Endoscopes in a Good Refurbished condition, We offer you an attractive price of all range of endoscopes, specifically in FUJIFILM & OLYMPUS. Some of the models are listed below for quick reference

Fujifilm

Processors:-


EPX 4400

VP-4400 Specification

Power 120V 60Hz 0.36A / 230V 50Hz 0.2A
Metering Mode Average / Peak
Gain Normal, +2dB, +4dB, +6dB
FreezeMode Field / Frame
Image Zoom Electronic Zoom x 1 - x2 (0.05 Steps)
Memory Patient data: 44 Patients /Clinical
Procedures: 20 types Dr. Name: 20
doctors / Dr. Page: 5 Patterns
Digital O/P DVI (Digital Visual Interface), USB,
Ethernet, CF (Compact Flash)
Analog O/P Composite, RGB, S-Video
Applicable Endoscopes FUJINON EVE 400 & 500 SERIES
Dimension 350 x 75 x 420mm
Weight 8 Kg


XL-4400 Specification

Power 120V 60Hz 4.1A / 230V 50Hz 2.1A
Lamp Rated Value Main Lamp : 15V 300W Xenon
Emergency Lamp: 12V 75W Halogen Lamp
Light Control Automatic IRIS
Air Pump Normal / Low / Off
Applicable Endoscopes FUJINON EVE 400 & 500 SERIES
Dimension 350 x 130 x 420mm
Weight 16 Kg



EPX 2200
EPX201H

Video Gastroscopes :-

EG590WR

EG 590 WR
Viewing Direction 0*(Forward)
Field Of View 140 deg
Observation Range 6-100 mm
Distal End Diameter 9.6 mm
Flexible Portion Diameter 9.3 mm
Bending Capability UP 210/DOWN 90/RIGHT 100/LEFT 100
Working Length 1,100 mm
Total Length 1,400 mm
Forceps Chennal Diameter 2.8 mm



EG450WR5

EG450WR5
Viewing Direction Forward
Field Of View 140 deg
Observation Range 4-100 mm
Distal End Diameter 9.4 mm
Flexible Portion Diameter 9.3 mm
Bending Capability UP 210/DOWN 90/RIGHT 100/LEFT 100
Working Length 1,100 mm
Total Length 1,400 mm
Forceps Chennal Diameter 2.8 mm



EG250WR5

EG250WR5
Viewing Direction Forward
Field Of View 140 deg
Observation Range 5-100 mm
Distal End Diameter 9.4 mm
Flexible Portion Diameter 9.3 mm
Bending Capability UP 210/DOWN 90/RIGHT 100/LEFT 100
Working Length 1,100 mm
Total Length 1,400 mm
Forceps Chennal Diameter 2.8 mm



EG201FP

EG201FP
Viewing Direction Forward
Field Of View 140 deg
Observation Range 6-100 mm
Distal End Diameter 9.0 mm
Flexible Portion Diameter 9.8 mm
Bending Capability UP 210/DOWN 90/RIGHT 100/LEFT 100
Working Length 1,100 mm
Total Length 1,400 mm
Forceps Chennal Diameter 2.8 mm



Video Colonoscopes:-

EC450WL5

EC450WL5
Viewing Direction Forward
Field Of View 140 deg
Observation Range 3-100 mm
Distal End Diameter 12.8 mm
Flexible Portion Diameter 12.8 mm
Bending Capability UP-DOWN 180/RIGHT-LEFT 160
Working Length 1,690 mm
Total Length 1,990 mm
Forceps Chennal Diameter 3.8 mm



EC250WL5

EC250WL5
Viewing Direction Forward
Field Of View 140 deg
Observation Range 3-100 mm
Distal End Diameter 12.8 mm
Flexible Portion Diameter 12.8 mm
Bending Capability UP-DOWN 180/RIGHT-LEFT 160
Working Length 1,690 mm
Total Length 1,990 mm
Forceps Chennal Diameter 3.8 mm



EC201WL



Video ERCP SCOPE :-

ED450XT5

ED450XT5
Viewing Direction Lateral(8*Rearward)
Field Of View 100 deg
Observation Range 4-60 mm
Distal End Diameter 13.1 mm
Flexible Portion Diameter 11.8 mm
Bending Capability UP 130/DOWN 90/RIGHT 110/LEFT 90
Working Length 1,250 mm
Total Length 1,550 mm
Forceps Chennal Diameter 4.2 mm



ED530XT

ED530XT
Viewing Direction 98*(8*Rearward)
Field Of View 100 deg
Observation Range 4-60 mm
Distal End Diameter 13.1 mm
Flexible Portion Diameter 11.5 mm
Bending Capability UP 130/DOWN 90/RIGHT 110/LEFT 90
Working Length 1,250 mm
Total Length 1,550 mm
Forceps Chennal Diameter 4.2 mm



2. OLYMPUS

Processor :-

CV180



CV150



CV 150 OLYMPUS VIDEOSCOPE SYSTEM
Observation video signal Output White Balance Adjusment Color Tone Adjustment Iris Mode Selection Image Enhancement Setting Y/C,RGB,VBS Composite,and XGA signal; Simultaneous Output is Possible. By Pressing the white balance switch on the front panel, automatic white balance can be performed. * "R" control :±7steps * "B" control: ±7steps Average:Normal observation, Peak:When focusion on and/or observing a small bright area. Fine pattems or edges in the endoscopic image can be enhancad electrically to increase the image sharpness. Either the structural enhancement or edge enhancement can be selected.
Documentation Patient Data The following data can be displayed on the video moniter using the keyboard. 1.Patitent ID number 2.Patient Name 3.Sex, Age 4.Date Of Birth 5.Comments.
IIIumination Switching Of Lamps Lamp A Lamp B Lamp Life lgnition Light output Adjustment Cooling Manual 150 W halogen lamp(MD-151: JCM 15-150FP, USHIO) Approx . 50 hours of continuous use. When used intermittently, the lamp life may vary slightly. Switching regulator Light-part diaphragm control Forced-air cooling
Air Feeding Pump
Airflow
Diaphragm type pump
"Low" ,"High","stop"
Power Supply Voltage
Frequency
PAL:220-240 V AC, NTSC : 100-120 V AC
50/60 HZ
Size Dimensions
Weight
295 (w) ×160 (H)×414(D) mm
13 Kg



CV160



C V-160
Observation Video signal output White balance Standard color chart output Digital communication port Color tone adjustment Automatic gain control (AGC) Contrast Iris mode selection Structure enhancement setting Edge enhancement setting Image size selection Default reset Freeze screen display VBS composite, Y/C, RGB; simultaneous output is possible. By pressing the white balance switch on the front panel, automatic white balance can be performed. After initialization, white balance settings are retained in memory for EVIS EXERA 160 Series scopes. The color bar image can be displayed using the“Color Bar”key on the keyboard. Ethernet (100BASE-TX) “CHROMA”control: ±7steps, “R”control: ±7steps, “B”control: ±7steps The image can be electrically amplified when the light is inadequate due to the distal end of the videoscope being too far from the subject. Normal Contrast mode: Normal image Low Contrast mode: The dark areas are lighter and the light areas are darker than in a normal image. High Contrast mode: The dark areas are darker and the light areas are lighter than in a normal image. Average: Normal observation Peak: When focusing on and/or observing a small bright area. The detailed patterns and edges of endoscopic images are emphasized electronically to increase image sharpness. The structure enhancement level can be switched between“Low”,“Medium”and“High”.􀀀 The edges of endoscopic images are emphasized electronically to increase image sharpness. The edge enhancement level can be switched between“Low”,“Medium”and“High”.􀀀 The size of endoscopic images can be changed using the“Image Size”key on the keyboard or endoscope switch. The following settings can be restored by pressing the“RESET”switch on the front panel.􀀀 Image Source, Iris, Enhancement, Color, AGC, Display mode, Contrast, Printer Lock, Keyboard mode, Printer mode, Printer QTY. A stationary image can be displayed using the endoscope switch, keyboard or OVC switch.
Documentation Remote control Patient data Pre-procedural patient data Recalling and registered scope information (scope ID function) The following ancillary equipment can be controlled by the endoscope remote switch, the front panel and the keyboard. (Only the specified device types are valid.) ・ Monitor ・ VTR ・ Video printer equipment ・ Digital video cassette recorder ・ Flushing pump The following data and modes can be displayed on the video monitor using the keyboard. 1. ID number 2. Patient name 3. Sex, age 4. Date of birth 5. Date/time (built-in clock, stopwatch) 6. Frame number 7. VTR condition 8. Picture quality selection 9. Physician 10. Comments For a maximum of 40 patients. 1. ID number 2. Patient name 3. Sex, age 4. Date of birth 5. Physician The following scope-related data stored in the memory chip of the scope can be recalled and displayed on the screen. Scope Model, Serial No., Comments, Cumulative Uses, Check Period, Service Contract, Warranty Date, Owner, Customer ID No., ID Ver.
Image storage and retrieval Monitor output Memorization of selected setting Using the monitor output switch on the front panel, it is possible to select an image from the endoscope or ancillary equipment for display on the monitor. The following settings on the front panel are retained even when the power is turned OFF. ・ Color ・ Enhancement ・ White balance ・ Iris
Classification (medical electrical equipment) Type of protection against electric shock Degree of protection against electric shock of applied part Class Type BF applied part (The applied part where classification types are not marked is Type BF applied part.)
Power Supply Voltage
Frequency
Input current
Fuse rating
NTSC 100—120 V AC, PAL 220—240 V AC
50/60 Hz
NTSC 1.0 A , PAL 0.5 A
3.15 A , 250 V
Size Dimensions
Weight
370 (W) X 72 (H) X 420 (D) mm
8 kg



CV140

Video Gastroscopes:-

GIF – Q140

GIF-140
Optical System Field Of View
Direction Of View
Depth Of View
120 deg
Forward
3-100mm
Insertion Tube IT Diameter 9.8mm
Angulation Up
Down
Right
Left
210 deg
90 deg
100 deg
100deg
Length Working Length
Total Length
103cm
133cm
Biopsy Chennal Chennal Size 2.8mm



GIF – Q150

GIF – Q160

GIF Q 160 Spec
Optical System Field Of View
Direction Of View
Depth Of View
140 deg
Forward
3-100mm
Insertion Tube IT Diameter 9.5mm
Angulation Up
Down
Right
Left
210 deg
90 deg
100 deg
100deg
Length Working Length
Total Length
103cm
134.5cm
Biopsy Chennal Chennal Size 2.8mm



GIF – Q180

GIF – Q180
Optical System Field Of View
Direction Of View
Depth Of View
140 deg
Forward
3-100mm
Insertion Tube IT Diameter 8.8mm
Angulation Up
Down
Right
Left
210 deg
90 deg
100 deg
100deg
Length Working Length
Total Length
103cm
134.5cm
Biopsy Chennal Chennal Size 2.8mm



Video Colonoscope

CF – Q140AL

Spec CF-140
Optical System Field Of View
Direction Of View
Depth Of View
140 deg
Forward
5-100mm
Insertion Tube IT Diameter 12.9mm
Angulation Up
Down
Right
Left
180 deg
180 deg
160 deg
160 deg
Length Working Length
Total Length
168cm
198cm
Biopsy Chennal Chennal Size 3.7mm



CF – Q150AL

CF – Q160AL

CF-Q160AL Specs
Optical System Field Of View
Direction Of View
Depth Of View
140 deg
Forward
3-100mm
Insertion Tube IT Diameter 12.8mm
Angulation Up
Down
Right
Left
180 deg
180 deg
160 deg
160 deg
Length Working Length
Total Length
168cm
200cm
Biopsy Chennal Chennal Size 3.7mm



CF – Q180AL

CF-Q180Al
Optical System Field Of View
Direction Of View
Depth Of View
170 deg
Forward
3-100mm
Insertion Tube IT Diameter 12.8mm
Angulation Up
Down
Right
Left
180 deg
180 deg
160 deg
160 deg
Length Working Length
Total Length
133cm
165.5cm
Biopsy Chennal Chennal Size 3.7mm



2. Endoscope Camera Systems

3. Accessories